Description
Suitable for products with a temperature between +02°C and +25°C
 
 
Thermal protection duration: Standard (1/5)

Manufactured by METTCOVER in a certified facility.
 
  
 
| Test | Value | Test Method | 
|---|---|---|
| Thickness, mm | 0.541 | By Vernier Caliper | 
| Density, Kg/m3 | 458.50 | ASTM C271 | 
| GSM | 350 | GSM SCALE | 
| Tensile Strength, N/mm2 | 8.19 | ASTM D638 | 
| Tear Resistance, KN/m | 72.1 | ASTM D624 | 
| Moisture Vapor Transmission, g/m2 per day | 0.0184 | ASTM E96 | 
| Water Pressure Resistance, cm H2O | 814 | ISO: 811-2018 | 
| Air Permeability, cm3/s/cm2 | 0.0 | ASTM D737 | 
| Flammability test, (Burning rate) mm/min | 253.54 | ASTM D635 | 
| Thermal Resistance, (R- Value), (m2-k/w) | 0.0117 | ASTM C177 | 
| Thermal Conductivity, W/m-K | 0.0462 | ASTM C177 | 
 
											


 
  
  
  
  
 